IUOE Plant Operator, 2nd Class
University of Rochester · Rochester, New York Metropolitan Area · 2 mo ago
Management$30.94–$40.23/hrFull-time
About the role
The University of Rochester is dedicated to the principle of Meliora - Ever Better, embodying values such as equity, leadership, integrity, openness, respect, and accountability. We strive to create a welcoming environment where all can thrive.
Responsibilities
- Takes over operations from the previous shift and acts as shift supervisor for efficient operation and maintenance of all major and auxiliary equipment.
- Observes all operating equipment, machines, tanks, meters, etc.
- Reads and records on daily log sheet all information required for initial hour of shift.
- Oversees Firemen on duty to assure efficient operation of boilers.
- Instructs Firemen in stationary engineering operations, procedures, and practices as further training for Firemen.
- Insures lubrication of all pumps, fans, compressors, emergency diesel-generator equipment, etc.
- Regularly checks all Dunham Control heating panels located in Central Plant.
- Receives and logs all trouble calls and transfer calls to appropriate personnel for service.
- Follows up service requests.
- Removes ash and siftings from boilers in use.
- Tests boiler water to determine amount of treatment to be added and/or blowdown required.
- Starts and stops chilled water unit as required and hourly logs chilled water unit readings (temperature, pressure, RPMs).
- As required, shuts down 4500 ton refrigeration unit and transfers refrigerant to storage receiver.
- Checks equipment (at pumping station) and cleans screens as necessary.
- Regularly inspects and observes all equipment for detection of mechanical malfunctioning.
- Makes repairs and adjustments to equipment as required.
- Changes recorder charts at 12 (M).
- Affords assistance in annual boiler cleaning.
- Keeps work area and equipment clean.
- Performs other related stationary operating duties as required or directed.
Qualifications
- High School graduation (preferably Trade School) plus a minimum of 3 years as a "Fireman-Stationary Boilers" which has included instruction and training in the overall operation and maintenance of a high pressure steam generation system and auxiliary equipment.
- Experience required could vary according to an individual's demonstrated abilities and aptitudes.
- Requires good judgment, good physical condition, and the willingness to work in an atmosphere where more than normal dirt, dust, and heat are present.