Central Eléctrica Power Plant
Llincorp auction services · Power, MT · 3 wk ago
Full-time
Contact: Leo Sosa / 809-543-3363 or 305-771-7750 – Email: sales@llincorp.com. For pricing, call 809-543-3363 or email sales@llincorp.com.
About the role
Our company advises corporate divestitures. Our clients are available to hear your offer at any time and negotiate favorable prices for the following power-plant equipment.
Equipment Listings – PP1 (General Electric 27.6 MW, 850 PSIG, 900°F)
- Motor Pumps: AC, DC, and TurboPump Lubricator oil
- Diesel Oil pumps (#1–#2): 1.5 HP, 5 GPM, 150 PSI, 440/220 V
- Booster Services Water pumps (#1–#2): 1,760 rpm, 220/440 V
- Feeding water pump (#1–#2): 500 HP, 610 GPM, 3,570 RPM, 440 V
- Circulation Water Pumps (#1–#2): 400 HP, 24,900 GPM, 710 RPM
- Make-up condensed water pump: 500 GPM, 3,550 RPM
- Revolving screen #1–#2
- Heater and Fuel oil Pumps #1–#2: 150 psi, 870 RPM
- Condensed Water Pump of recollected: 1,760 rpm, 95 GPM
- Modulate Control DCS BAILEY
- Pumps cooling water #1–#2: 25 HP, 1,765 RPM, 700 GPM
- Centrifuge Lubrication Oil: 1.5 HP, 1,730 RPM, 230/460 V
- Chemical Injection Pump and tanks: 100–150 psi, 13.3 GPM, 0.33–0.75 HP
- Washer Screen Pumps: 25 HP, 300 GPM, 3,500 RPM
- Condensed Water Pumps: 450 GPM, 60 HP
- Fan forced Throw: 350 HP, 1,775 RPM, 83,500 CFM, 440 V, 427 A
- Burner Boiler Starting Transformer: GE 2,000 kVA
- Auxiliary Transformer: GE 2,000 kVA
- Main Transformer: GE 33,600 kVA
- Main Switch: Power Systems Inc. 72.5 kV
- Traveling Crane: 5–25 TN, 10 HP SHAW BOX
- Boiler: Babcock Wilcox Company, 1,050 psig, 18,113 ft², 260,000 lb/hr
- Deaerator and Storage Tank: Condensed, 179,000 lbs, 4,800 tubes
Equipment Listings – PP2 (Westinghouse 36.7 MW Steam Turbine Generator)
- Motor Pumps: AC, DC, and Turbo Pump, 75 GPM
- Chemical Injection Pumps and tanks
- Centrifugal Lubrication Oil
- Fan Forced: 900 HP, 118,100 cfm (Westinghouse)
- Ingersoll Rand Compressor Centac #1–#2
- Heater and fuel oil Pumps #1–#2: 75 GPM, 1,180 RPM
- Condensed Water Pumps: 620 GPM, 60 HP
- Cooling Water #1–#2: 900 GPM, 60 HP
- Deaerator and storage tank
- Flame Blower: 3,475 RPM, 5 HP
- Feeding Water Pumps #1–#2: 900 HP, 1,485 PSI (Westinghouse)
- Diesel Oil Pumps #1–#2: 7 GPM, 1.5 HP
- Condensed Water Pumps of recollector: 40 GPM, 10 HP
- Circulator Water Pumps #1–#2: 28,000 GPM
- Washed Screen Pumps #1–#2: 250 GPM, 20 HP
- Revolving Screen #1–#2: 50 ft deep
- Serviced Water Pumps #1–#2: 225 GPM
- Makeup Condensed Water Pump: 75 GPM
- Generator Seal Systems
- Traveling Crane: 40/5 Tns, Sherard Niles Corp.
- Burners Oils
- Disconnecting Switch
- Charge and Bank Battery
- Transformer Bus Bar: 1,000/1,150 kVA #1–#2 (Westinghouse)
- Main Transformer: 30,000/40,000 kVA
- Auxiliary Transformer
- Starting Transformer: 8,000/10,000 kVA
- Main Switch
- Starting Transformer Main Switch: Edison Power Systems 72.5 kV
- Boiler: Combustion Engineering Inc.
- Condensed General Data: 26,280 sq ft, 6,375 tubes, 7/8 in (Westinghouse)